Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/8292
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSILVA, Roberto Chaves da-
dc.creator.Latteshttp://lattes.cnpq.br/0800736060567611por
dc.contributor.advisor1GUISELINI, Cristiane-
dc.contributor.advisor-co1VIGODERIS, Ricardo Brauer-
dc.contributor.referee1CHAVES, Josenildo de Souza-
dc.contributor.referee2ALMEIDA, Gledson Luiz Pontes de-
dc.contributor.referee3PANDORFI, Héliton-
dc.date.accessioned2019-10-23T13:33:37Z-
dc.date.issued2015-02-20-
dc.identifier.citationSILVA, Roberto Chaves da. Simulação e comparação de sistemas de ventilação por meio da dinâmica de fluidos computacional em ambiente protegido. 2015. 78 f. Dissertação (Programa de Pós-Graduação em Engenharia Agrícola) - Universidade Federal Rural de Pernambuco, Recife.por
dc.identifier.urihttp://www.tede2.ufrpe.br:8080/tede2/handle/tede2/8292-
dc.description.resumoObjetivou-se com este estudo modelar e simular, por meio de técnicas de dinâmica de fluido computacional (CFD), a interação do ambiente externo e interno de um ambiente protegido, e assim validar as variáveis micrometeorológicas monitoradas, para posterior comparação entre a ventilação natural e a indireta por permutadores de calor através do solo. O estudo contou com um ambiente protegido com cobertura de polietileno de baixa densidade (150 μm), com dimensões de 7,0 m de largura, 21,0 m de comprimento, 3,0 m de pé-direito e altura total de 4,5 m, localizado no município do Recife, PE, no campus da Universidade Federal Rural de Pernambuco. A primeira fase da pesquisa foi atribuída ao monitoramento e análise das variáveis micrometeorológicas, radiação solar global (Qg), temperatura do ar (Tar) e umidade relativa do ar (UR), registradas por meio de datalogger a cada 15 min. A segunda fase consistiu na modelagem numérica de volumes finitos do ambiente protegido com validação por meio dos dados registrados, para simular os dois sistemas de ventilação propostos. Os resultados da modelagem tiveram boa concordância nas relações comparativas entre os valores medidos e os simulados, com coeficientes de determinação (R²) para Qg de 0,97, Tar de 0,93 e UR de 0,93. O sistema indireto por meio de permutadores de calor através do solo apresentou melhor performance na redução da Tar de até em 4 oC e na redução da UR de 15%, já o sistema de ventilação natural possibilitou a redução da Tar em 1 ºC, com a manutenção da UR. O uso das técnicas CFD permitiu modelar e caracterizar o ambiente protegido, assim como simular os sistemas de ventilação propostos.por
dc.description.abstractThe objective of this study was to model and to simulate, using CFD techniques, a greenhouse trough the interaction of the external environment with the internal environment, and thus describe the main monitored variables: solar radiation (Qg, W m-2), temperature of the air (Tar, °C) and relative humidity (RH%). After the validation of these models, to develop simulations of two ventilation systems (a) Natural ventilation system and (b) evaporative heat exchange system through the soil to compare and predict the microclimatic variations. The study was conducted in two phases. First, monitoring and analysis of meteorological variables of a environment located in Recife, on the campus of Rural Federal University of Pernambuco, with plastic cover (low density polyethylene) and geometric characteristics of 7.0 m wide, 21.0 m long, 3.0 m high-ceiling and 4.5 m in total height. The second phase consisted in numerical modeling of greenhouse finite volumes and thus to validate the model using the experimental data, and finally to simulate the two ventilation systems. The modeling results generally have shown good agreement in the comparative relationships between measured and simulated values, with coefficients of determination (R²) of 0.9722 for Qg, 0.9347 for Tar, and 0.9392 for RH. In the simulations of the ventilation systems, the indirect evaporative system using heat exchangers through the soil have shown the best performance in reducing Tar at 4 °C and reduced by 15% the RH. The natural ventilation system by opening the roof axis was able to reduce the Tar by 1 °C and kept the relative humidity stable. It was concluded that with the use of CFD techniques it was possible to model and to characterize the greenhouse, and to simulate ventilation systems in order to improve the conditions of temperature and relative humidity.eng
dc.description.provenanceSubmitted by Mario BC (mario@bc.ufrpe.br) on 2019-10-23T13:33:37Z No. of bitstreams: 1 Roberto Chaves da Silva.pdf: 1602139 bytes, checksum: 7677ab728b3a7e7f2f849d3d97659ef3 (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-10-23T13:33:37Z (GMT). No. of bitstreams: 1 Roberto Chaves da Silva.pdf: 1602139 bytes, checksum: 7677ab728b3a7e7f2f849d3d97659ef3 (MD5) Previous issue date: 2015-02-20eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Federal Rural de Pernambucopor
dc.publisher.departmentDepartamento de Engenharia Agrícolapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUFRPEpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Agrícolapor
dc.rightsAcesso Abertopor
dc.subjectCultivo protegidopor
dc.subjectDinâmica de fluido computacionalpor
dc.subjectMicrometeorologiapor
dc.subjectSistema de ventilaçãopor
dc.subject.cnpqCIENCIAS AGRARIAS::ENGENHARIA AGRICOLApor
dc.titleSimulação e comparação de sistemas de ventilação por meio da dinâmica de fluidos computacional em ambiente protegidopor
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Engenharia Agrícola

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Roberto Chaves da Silva.pdfDocumento principal1,56 MBAdobe PDFBaixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.