Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5850
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | FERRI, Rinaldo Cavalcante | - |
dc.creator.Lattes | http://lattes.cnpq.br/3672392528239713 | por |
dc.contributor.advisor1 | SÁ, Fabrício Bezerra de | - |
dc.contributor.referee1 | SILVA, Jean Carlos Ramos da | - |
dc.contributor.referee2 | VAZ, Beatriz Berlinck d′Utra | - |
dc.contributor.referee3 | SOUZA, Rute Chamié Alves de | - |
dc.date.accessioned | 2016-11-04T11:57:27Z | - |
dc.date.issued | 2007-02-28 | - |
dc.identifier.citation | FERRI, Rinaldo Cavalcante. Eletrocardiografia em quatis (Nasua nasua – Linnaeus, 1766) mantidos em ativeiro e contidos quimicamente com quetamina e xilazina. 2007. 106 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife. | por |
dc.identifier.uri | http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5850 | - |
dc.description.resumo | Este trabalho teve por objetivo avaliar o perfil eletrocardiográfico de 21 quatis (Nasua nasua - Linnaeus, 1766) mantidos em cativeiro, sob contenção química utilizando quetamina e xilazina. Foram analisadas as variáveis: freqüência cardíaca (FC), ritmo, eixo elétrico médio (EEM) onda P, complexo QRS, intervalo PR e QT, segmento ST e onda T. Os resultados encontrados foram: FC (157,62±28,22 bpm); onda P (0,058±0,021 mV e 0,03±0,0056 seg); PR (0,07±0,0097 seg); QRS (0,551±0,20 mV e 0,0335±0,0055 seg); e QT (0,165±0,017 seg). O ritmo dominante foi o sinusal normal (90,48%), no entanto, um animal apresentou padrão sugestivo de bloqueio fascicular anterior esquerdo. Dois animais (9,52%) apresentaram arritmia sinusal com marcapasso migratório. O EEM variou de -30û a +90û, com 90,48% dos animais mostrando-se dentro do intervalo +60û a +90û. Os valores observados para os quatis foram similares aos do gato (mensurações e configurações do complexo P-QRS-T) e cão domésticos (EEM). | por |
dc.description.abstract | The objective of this work is to evaluate electrocardiographic profile in 21 coatis(Nasua nasua - Linnaeus, 1766) kept in captivity, undergoing anesthetic protocol with ketamine and xylazine. The variables analyzed were: Heart rate (HR), rhythm, mean electrical axis (MEA), P wave, QRS complex, PR and QT interval, ST segment and T wave. Results showed: FC (157.62±28.22 bpm); P(0.058±0.021 mV and 0.03±0.0056 sec.); PR (0.07±0.0097 sec.); QRS (0.551±0.20 mV and 0.0335±0.0055 sec.); QT (0.165±0.017 sec.). Normal sinus rhythm was dominant (90.48%), however, animal one presented suggestive pattern of left anterior fascicle block. Two animals had sinus arrhythmia with wandering pacemaker (9.52%). The MEA varied from -30û a + 90û with a more frequent interval (90.48%) from +60û a +90û. The values observed for the coatis were similar to those of domestic cats (voltage and P-QRS complex) and domestic dogs (MEA). | eng |
dc.description.provenance | Submitted by (edna.saturno@ufrpe.br) on 2016-11-04T11:57:27Z No. of bitstreams: 1 Rinaldo Cavalcante Ferri.pdf: 4667248 bytes, checksum: 15ff7a13da0ce505b67053e3661090da (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2016-11-04T11:57:27Z (GMT). No. of bitstreams: 1 Rinaldo Cavalcante Ferri.pdf: 4667248 bytes, checksum: 15ff7a13da0ce505b67053e3661090da (MD5) Previous issue date: 2007-02-28 | eng |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | por |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Federal Rural de Pernambuco | por |
dc.publisher.department | Departamento de Medicina Veterinária | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UFRPE | por |
dc.publisher.program | Programa de Pós-Graduação em Ciência Veterinária | por |
dc.rights | Acesso Aberto | por |
dc.subject | Quati | por |
dc.subject | Eletrocardiografia | por |
dc.subject | Quatamina | por |
dc.subject | Xilazina | por |
dc.subject | Coati | eng |
dc.subject | Electrocardiography | eng |
dc.subject | Ketamine | eng |
dc.subject | Xylazine | eng |
dc.subject.cnpq | CIENCIAS AGRARIAS::MEDICINA VETERINARIA | por |
dc.title | Eletrocardiografia em quatis (Nasua nasua – Linnaeus, 1766) mantidos em ativeiro e contidos quimicamente com quetamina e xilazina | por |
dc.title.alternative | Electrocardiography in coatis (Nasua nasua - Linnaeus, 1766) maintained in captivity and contained chemically with ketamine and xylazine | eng |
dc.type | Dissertação | por |
Aparece nas coleções: | Mestrado em Ciência Veterinária |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Rinaldo Cavalcante Ferri.pdf | Documento principal | 4,56 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.